BARRIGEL™
RECTAL SPACER

The Material Difference In Spacing1-4

Barrigel rectal spacer is made from non-animal stabilized hyaluronic acid (NASHA) formulated for the strength to separate and lift tissue.2-4

  • The sculptable gel gives you the ability to refine and adjust the implant without injection time constraints.1-2,5-6

  • Viscoelastic gel bends, stretches and reforms with the body’s natural movements, while maintaining shape throughout the course of treatment.2-3†

  • In the Barrigel Pivotal Trial, there were ZERO patient complaints of device-related pain or discomfort1

SAFE SPACING
FROM IMPLANT TO OUTCOMES1-2,5-7

SAFE SPACING FROM
IMPLANT TO OUTCOMES1-2,5-7

HIGHLY VISIBLE

REAL-TIME SCULPTABILITY5-6

  • Visualize how much space you’re creating in real-time and personalize the implant to each patient’s anatomy, ensuring optimal coverage.1-2,5-7

HIGHLY VISIBLE

NO INJECTION TIME LIMIT1-2,5-6

  • Take your time building a symmetrical, even implant.2,5-6*

  • Pause and perform safety checks throughout the procedure.1,5

HIGHLY VISIBLE

HIGHLY VISIBLE1-2,5-6

  • Hypoechoic properties ensure high visibility on TRUS imaging for a clear view of Barrigel spacer as you sculpt the implant in real-time.1-2,5-6

HIGHLY VISIBLE

SAFE OUTCOMES

  • Pivotal Trial Results: Proven superior in the reduction of acute Grade 2+ GI toxicity compared to control1

  • 3-Year Results (ESTRO 2026 Abstract): ZERO long-term Grade 2+ GI toxicities compared to control8

HOW BARRIGEL SPACER WORKS

HOW BARRIGEL SPACER WORKS


EVALUATING YOUR RECTAL
SPACER OPTIONS

EVALUATING YOUR RECTAL
SPACER OPTIONS

The data points provided below are for educational purposes only. No head-to-head study has been performed. Results are from various clinical studies and sources and are not directly comparable.

Barrigel™ Rectal Spacer FDA-Cleared 05/2022 PEG Hydrogel FDA-Granted 04/2015 PEG Hydrogel w/ Iodine FDA-Cleared 07/2019 Balloon FDA-Cleared 08/2023
Sculptable, Controllable Gel Yes1 No5 No5 No12
No Injection Time Constraints Yes(remains viscous)1 No(polymerization in 8–10 seconds)6 No(polymerization in 12–15 seconds)10 Yes12
Real-Time Analysis Yes1 No No Yes12
Symmetrical Implant Placement Yes(95.6%)2* No(49%)7 Symmetry Data NR Symmetry Data NR
Post-Procedure Reversibility Yes(dissolvable with hyaluronidase)3 No3 No3 No
Simple Assembly & Procedure Yes4 No5 No5 No12
Image Visibility
TRUS High1 Low8** Low11** High12
MR Yes Yes Yes Yes
CT Yes(settings dependent) Limited(blends with soft tissue)9 Yes Yes
Features
Sculptable, Controllable Gel
Barrigel™
Yes1
PEG Hydrogel
No5
PEG Hydrogel w/ Iodine
No5
Balloon
No12
No Injection Time Constraints
Barrigel™
Yes(remains viscous)1
PEG Hydrogel
No(polymerization in 8–10 seconds)6
PEG Hydrogel w/ Iodine
No(polymerization in 12–15 seconds)10
Balloon
Yes12
Real-Time Analysis
Barrigel™
Yes1
PEG Hydrogel
No
PEG Hydrogel w/ Iodine
No
Balloon
Yes12
Symmetrical Implant Placement
Barrigel™
Yes(95.6%)2*
PEG Hydrogel
No(49%)7
PEG Hydrogel w/ Iodine
Symmetry Data NR
Balloon
Symmetry Data NR
Post-Procedure Reversibility
Barrigel™
Yes(dissolvable with hyaluronidase)3
PEG Hydrogel
No3
PEG Hydrogel w/ Iodine
No3
Balloon
No
Simple Assembly & Procedure
Barrigel™
Yes4
PEG Hydrogel
No5
PEG Hydrogel w/ Iodine
No5
Balloon
No12
Image Visibility
TRUS
Barrigel™
High1
PEG Hydrogel
Low8**
PEG Hydrogel w/ Iodine
Low11**
Balloon
High12
MR
Barrigel™
Yes
PEG Hydrogel
Yes
PEG Hydrogel w/ Iodine
Yes
Balloon
Yes
CT
Barrigel™
Yes(settings dependent)
PEG Hydrogel
Limited(blends with soft tissue)9
PEG Hydrogel w/ Iodine
Yes
Balloon
Yes

*In a separate, directly analogous secondary analysis of data from the Barrigel pivotal trial, Barrigel symmetry results were compared to those of SpaceOAR, as reported in Fischer-Valuck BW et al. Pract Radiat Oncol (2017), using the same methodology used in that study. Information provided for educational purposes only. No head-to-head study has been performed. Results from different clinical studies are not directly comparable.
**Air from injection may distort image.

References For This Table
  1. 1.Mariados NF, Orio PF III, King M et al. JAMA Oncol (2023).†§
  2. 2.Svatos M, Chell E, Low DA et al. Med Phys (2024).†§
  3. 3.Hong A, Ischia J, Chao M. Front Oncol (2022).§
  4. 4.Barrigel Injectable Gel Instructions for Use (2022).
  5. 5.SpaceOAR® System Product Code SO-31-1 Instructions for Use. Bedford, MA: Augmenix; Rev C.
  6. 6.What every urologist needs to know about SpaceOAR® hydrogel: How Augmenix is improving QOL for prostate cancer patients. Urology Times. Supplement. May 2018.
  7. 7.Fischer-Valuck BW, Chundury A, Gay H, Bosch W, Michalski J. Pract Radiat Oncol (2017).§
  8. 8.Boston Scientific. SpaceOAR™ System Indications, Safety, and Warnings. 2022. URO-819103-AB-JUN 2022.
  9. 9.Boston Scientific. SpaceOAR™ Hydrogel: Advancing radiation therapy – SpaceOAR™ Vue across different radiation modalities. (Accessed 04/01/2022).
  10. 10.Boston Scientific. Application Technique for SpaceOAR Vue™ Hydrogel: Dr. Asunció Hervas, Dr. José Dominguez. 2021. Accessed: January 1, 2026. https://www.bostonscientific.com/en-EU/medical-specialties/urology/hydrogel-spacing/learn-from-experts.html.
  11. 11.Boston Scientific. SpaceOAR™ Vue System Indications, Safety, and Warnings. 2022. URO-855204-AB JUN 2022.
  12. 12.BioProtect.com (Accessed 1/1/2026).

†Study sponsored by Palette Life Sciences, now part of Teleflex.
§One or more of the authors are paid consultants of Teleflex.

HEAR FROM BARRIGEL SPACER PHYSICIANS**

“Barrigel spacer is the only rectal spacer I use in my practice…based on my experience, the data, patient safety, and results we’ve seen.”

– Zachary Klaassen, MD, MSc, Urologic Oncologist, Georgia Cancer Center

Using Barrigel™ rectal spacer, I really find that I can get what I want. I can really customize it the way I want to. I don't have to worry about time of delivery.

– Michael J. Greenberg, MD, Radiation Oncologist at Jefferson Health, Philadelphia, PA

*In a secondary analysis of data from the Barrigel pivotal trial, 95.6% of implants were found to be symmetric using the methodology from Fischer-Valuck BW et al. Pract Radiat Oncol (2017).
†On average through 3 months

** This information reflects the personal experiences and professional medical opinions of the featured healthcare providers. Results may vary. All featured physicians are paid consultants of Teleflex.

 

References

  • 1. Mariados NF, Orio PF III, King MT et al. JAMA Oncol (2023).‡§

    2. Svatos M, Chell E, Low DA et al. Med Phys (2024).‡§

    3. Barrigel Injectable Gel Instructions for Use (2022).

    4. Data on file.

    5. Gejerman G, Goldstein MM, Chao M et al. Pract Radiat Oncol (2023).§

    6. Williams J, Mc Millan K, Chao M et al. J Med Imag Radiat Sci (2022).§

    7. King MT, Svatos M, Orio PF III et al. Pract Radiat Oncol (2023).‡§

    8. King M, Chao M et al. Prospective Randomized Controlled Trial of Hyaluronic Acid Spacer for Hypofractionated Prostate Radiation Therapy: 3-Year Results. Presented at: European Society for Radiotherapy and Oncology 2026 Annual Congress; May 2026; Stockholm, Sweden. Proffered Paper 3623. ‡§

    ‡ Study sponsored by Palette Life Sciences, now part of Teleflex.

    § One or more of the authors are paid consultants of Teleflex. 

APMC088-02A